{"id":6497,"date":"2024-12-20T17:48:24","date_gmt":"2024-12-20T17:48:24","guid":{"rendered":"https:\/\/beckerpumps.com\/latam\/?p=6497"},"modified":"2025-09-23T16:21:29","modified_gmt":"2025-09-23T16:21:29","slug":"how-to-wire-a-vacuum-pump","status":"publish","type":"post","link":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/","title":{"rendered":"How to Wire Your Vacuum Pump Properly"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">To wire a Becker vacuum pump, follow common practices for wiring a 3-phase induction motor with 9 post terminals.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The most common motor design for industrial pumps uses three phases of alternating current offset from each other by 120 degrees. Each phase is connected to two copper wire windings. As electrical current from the power source flows through the windings, it drives the mechanical rotation of the motor.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">HOW TO WIRE A VACUUM PUMP<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Check the nameplate or tag on the motor to find out the voltage(s) and current that it can handle. Depending on the motor type, the nameplate could show the wiring diagram printed on the motor tag or the schematic could be found inside of the terminal box. This will guide you on the proper way to connect the leads.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The diagram will show the corresponding configuration for the allowed voltages. On the wiring diagram, you will see three incoming leads labeled L1, L2, and L3. These are the three phases of electricity coming in through wires in the power cable.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The terminals are typically labeled U1, V1, W1, U2, V2, W2, U5, V5, and W5, and can be found in the terminal box located on the motor. These symbols are given to the 9 wire pin terminals, which serve as connection points between the windings in the motor.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Becker vacuum pump motors can operate at many voltage options. For example, in North America, we use 208V-230V and 460V+-10%. The windings in the motor can be wired either for high voltage or low voltage.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on the voltage of the main power, the leads can be wired together in two different configurations: low voltage (called Delta or WYE) or high voltage (called WYE).<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ratio ratio-16x9\"><iframe title=\"How to Wire a Vacuum Pump\" width=\"500\" height=\"281\" data-src=\"https:\/\/www.youtube.com\/embed\/iS9i-Lr8nGY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" data-load-mode=\"0\"><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">BECKER VACUUM PUMP WIRING DIAGRAMS<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>NOTE: <\/strong>Work on the electrical wiring system should only be carried out by qualified electricians.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Practice common safety precautions, including lock-out and tag-out, before beginning any work on the electrical motor. Switch off the pump and any connected components and disconnect them from the supply voltage. Then disconnect the pump from the air supply.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For most 3-phase Becker vacuum pump models, configure the jumper bars like this depending on the applied voltage:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"255\" height=\"185\" data-src=\"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/Becker-Voltage-Specs.png\" alt=\"Vacuum pump wiring voltage specifications\" class=\"wp-image-6500 lazyload\" data-srcset=\"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/Becker-Voltage-Specs.png 255w, https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/Becker-Voltage-Specs-200x145.png 200w, https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/Becker-Voltage-Specs-207x150.png 207w\" data-sizes=\"(max-width: 255px) 100vw, 255px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 255px; --smush-placeholder-aspect-ratio: 255\/185;\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Match the diagram to the voltage level of your power source. Note that jumper bars can be configured for different applied voltages, so ensure you use the correct configuration.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Next, connect the leads from the mains power to your motor starter\/protection or VFD to U1, V1, and W1 and connect the ground wire to the ground.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">TESTING THE MOTOR<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Once the wiring is complete, remove the lock-out tag-out and reconnect the power. Then quickly bump power to start and stop the motor. The motor will rotate allowing for visual checking of the motor fan rotation. Ensure the motor fan spins in the correct direction, as indicated by the rotation arrows found on the pump.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If the fan rotates in the wrong direction, you will need to reverse the polarity of the motor. Before doing this, turn off the main power to the system and lock out, tag out once again. Then switch any two of the leads, for example, switch L1 and L3. Reconnect the power and test again to ensure the pump rotates in the correct direction.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Once the pump is rotating properly, allow the motor to run while measuring the voltage and current to ensure they are within the proper range. At the same time, listen for any <a href=\"https:\/\/beckerpumps.com\/latam\/news\/what-to-do-if-your-vacuum-pump-is-making-a-loud-noise\/\">unusual noises<\/a> that may indicate problems inside the pump.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>CAUTION:<\/strong> Do not start the pump motor more than six times an hour, as this may cause damage to the vanes or the pump.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">BECKER VACUUM PUMP WIRING SPECIFICATIONS<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Becker pump models operate on specific voltage and amperage ratings. The necessary wire size varies based on the power supply voltage. For instance, the VTLF 2.250SK model requires a size 8 AWG wire when powered by 230V and a 12 AWG wire for 460V operation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Please refer to the chart below for general specifications. It&#8217;s crucial to consult a qualified electrician to verify the appropriate wiring size and ensure safe and compliant installation in your specific facility.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"932\" height=\"410\" data-src=\"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/Becker-Motor-Specs.png\" alt=\"Becker vacuum pump wiring specifications\" class=\"wp-image-6502 lazyload\" data-srcset=\"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/Becker-Motor-Specs.png 932w, https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/Becker-Motor-Specs-300x132.png 300w, https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/Becker-Motor-Specs-768x338.png 768w, https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/Becker-Motor-Specs-200x88.png 200w\" data-sizes=\"(max-width: 932px) 100vw, 932px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 932px; --smush-placeholder-aspect-ratio: 932\/410;\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">CONTACT THE VACUUM PUMP EXPERTS AT BECKER FOR TECHNICAL SUPPORT<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">At Becker Pumps, we are known globally as experts in manufacturing and servicing high-quality vacuum pumps for a wide range of industries. We provide <a href=\"https:\/\/beckerpumps.com\/latam\/service\/mobile-service\/\">mobile service<\/a> and customer support, including <a href=\"https:\/\/www.becker-international.com\/de\/en\/295\/training.htm\">training<\/a> that covers vacuum and pump basics, electrical engineering, specific product training, and everything in between.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Call Becker Pumps&#8217; Technical Support team today for assistance with your vacuum pump wiring needs.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"tel:3309166853\">CALL US<\/a><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>To wire a Becker vacuum pump, follow common practices for wiring a 3-phase induction motor with 9 post terminals.&nbsp; The most common motor design for industrial pumps uses three phases of alternating current offset from each other by 120 degrees. Each phase is connected to two copper wire windings. As&#8230;<\/p>\n","protected":false},"author":7,"featured_media":6499,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_becker_theme_hero_title":"","_becker_theme_hero_sub_title":"","footnotes":""},"categories":[200,205],"tags":[],"class_list":["post-6497","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-pumps","category-support-training"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Wire Your Vacuum Pump Properly - Becker Latin America<\/title>\n<meta name=\"description\" content=\"Learn the steps to wire a Becker vacuum pump safely and effectively, including voltage configuration and wiring diagram tips for 3-phase induction motors.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Wire Your Vacuum Pump Properly - Becker Latin America\" \/>\n<meta property=\"og:description\" content=\"Learn the steps to wire a Becker vacuum pump safely and effectively, including voltage configuration and wiring diagram tips for 3-phase induction motors.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/\" \/>\n<meta property=\"og:site_name\" content=\"Becker Latin America\" \/>\n<meta property=\"article:published_time\" content=\"2024-12-20T17:48:24+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-23T16:21:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/AdobeStock_224563725.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1592\" \/>\n\t<meta property=\"og:image:height\" content=\"1195\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Jick Libot\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jick Libot\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/\"},\"author\":{\"name\":\"Jick Libot\",\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/#\\\/schema\\\/person\\\/b7a719180b13fa1d6f21e90a0aebe429\"},\"headline\":\"How to Wire Your Vacuum Pump Properly\",\"datePublished\":\"2024-12-20T17:48:24+00:00\",\"dateModified\":\"2025-09-23T16:21:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/\"},\"wordCount\":789,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2024\\\/12\\\/AdobeStock_224563725.jpg\",\"articleSection\":[\"Vacuum Pumps\",\"Support &amp; Training\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/\",\"url\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/\",\"name\":\"How to Wire Your Vacuum Pump Properly - Becker Latin America\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2024\\\/12\\\/AdobeStock_224563725.jpg\",\"datePublished\":\"2024-12-20T17:48:24+00:00\",\"dateModified\":\"2025-09-23T16:21:29+00:00\",\"description\":\"Learn the steps to wire a Becker vacuum pump safely and effectively, including voltage configuration and wiring diagram tips for 3-phase induction motors.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/#primaryimage\",\"url\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2024\\\/12\\\/AdobeStock_224563725.jpg\",\"contentUrl\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2024\\\/12\\\/AdobeStock_224563725.jpg\",\"width\":1592,\"height\":1195,\"caption\":\"Vacuum pump motor wiring\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/how-to-wire-a-vacuum-pump\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Wire Your Vacuum Pump Properly\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/#website\",\"url\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/\",\"name\":\"Becker Latin America\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/#organization\",\"name\":\"Becker Latin America\",\"url\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2021\\\/10\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/wp-content\\\/uploads\\\/sites\\\/5\\\/2021\\\/10\\\/logo.png\",\"width\":2320,\"height\":575,\"caption\":\"Becker Latin America\"},\"image\":{\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/#\\\/schema\\\/person\\\/b7a719180b13fa1d6f21e90a0aebe429\",\"name\":\"Jick Libot\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/15b3ed15c569b3f07d9b76fc5e0d3363b1990121a964585e558ba5cb46d0a864?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/15b3ed15c569b3f07d9b76fc5e0d3363b1990121a964585e558ba5cb46d0a864?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/15b3ed15c569b3f07d9b76fc5e0d3363b1990121a964585e558ba5cb46d0a864?s=96&d=mm&r=g\",\"caption\":\"Jick Libot\"},\"url\":\"https:\\\/\\\/beckerpumps.com\\\/latam\\\/news\\\/author\\\/jickwebstrategiesinc-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Wire Your Vacuum Pump Properly - Becker Latin America","description":"Learn the steps to wire a Becker vacuum pump safely and effectively, including voltage configuration and wiring diagram tips for 3-phase induction motors.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/","og_locale":"en_US","og_type":"article","og_title":"How to Wire Your Vacuum Pump Properly - Becker Latin America","og_description":"Learn the steps to wire a Becker vacuum pump safely and effectively, including voltage configuration and wiring diagram tips for 3-phase induction motors.","og_url":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/","og_site_name":"Becker Latin America","article_published_time":"2024-12-20T17:48:24+00:00","article_modified_time":"2025-09-23T16:21:29+00:00","og_image":[{"width":1592,"height":1195,"url":"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/AdobeStock_224563725.jpg","type":"image\/jpeg"}],"author":"Jick Libot","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Jick Libot","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/#article","isPartOf":{"@id":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/"},"author":{"name":"Jick Libot","@id":"https:\/\/beckerpumps.com\/latam\/#\/schema\/person\/b7a719180b13fa1d6f21e90a0aebe429"},"headline":"How to Wire Your Vacuum Pump Properly","datePublished":"2024-12-20T17:48:24+00:00","dateModified":"2025-09-23T16:21:29+00:00","mainEntityOfPage":{"@id":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/"},"wordCount":789,"commentCount":0,"publisher":{"@id":"https:\/\/beckerpumps.com\/latam\/#organization"},"image":{"@id":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/#primaryimage"},"thumbnailUrl":"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/AdobeStock_224563725.jpg","articleSection":["Vacuum Pumps","Support &amp; Training"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/","url":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/","name":"How to Wire Your Vacuum Pump Properly - Becker Latin America","isPartOf":{"@id":"https:\/\/beckerpumps.com\/latam\/#website"},"primaryImageOfPage":{"@id":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/#primaryimage"},"image":{"@id":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/#primaryimage"},"thumbnailUrl":"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/AdobeStock_224563725.jpg","datePublished":"2024-12-20T17:48:24+00:00","dateModified":"2025-09-23T16:21:29+00:00","description":"Learn the steps to wire a Becker vacuum pump safely and effectively, including voltage configuration and wiring diagram tips for 3-phase induction motors.","breadcrumb":{"@id":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/#primaryimage","url":"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/AdobeStock_224563725.jpg","contentUrl":"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2024\/12\/AdobeStock_224563725.jpg","width":1592,"height":1195,"caption":"Vacuum pump motor wiring"},{"@type":"BreadcrumbList","@id":"https:\/\/beckerpumps.com\/latam\/news\/how-to-wire-a-vacuum-pump\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/beckerpumps.com\/latam\/"},{"@type":"ListItem","position":2,"name":"How to Wire Your Vacuum Pump Properly"}]},{"@type":"WebSite","@id":"https:\/\/beckerpumps.com\/latam\/#website","url":"https:\/\/beckerpumps.com\/latam\/","name":"Becker Latin America","description":"","publisher":{"@id":"https:\/\/beckerpumps.com\/latam\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/beckerpumps.com\/latam\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/beckerpumps.com\/latam\/#organization","name":"Becker Latin America","url":"https:\/\/beckerpumps.com\/latam\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/beckerpumps.com\/latam\/#\/schema\/logo\/image\/","url":"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2021\/10\/logo.png","contentUrl":"https:\/\/beckerpumps.com\/latam\/wp-content\/uploads\/sites\/5\/2021\/10\/logo.png","width":2320,"height":575,"caption":"Becker Latin America"},"image":{"@id":"https:\/\/beckerpumps.com\/latam\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/beckerpumps.com\/latam\/#\/schema\/person\/b7a719180b13fa1d6f21e90a0aebe429","name":"Jick Libot","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/15b3ed15c569b3f07d9b76fc5e0d3363b1990121a964585e558ba5cb46d0a864?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/15b3ed15c569b3f07d9b76fc5e0d3363b1990121a964585e558ba5cb46d0a864?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/15b3ed15c569b3f07d9b76fc5e0d3363b1990121a964585e558ba5cb46d0a864?s=96&d=mm&r=g","caption":"Jick Libot"},"url":"https:\/\/beckerpumps.com\/latam\/news\/author\/jickwebstrategiesinc-com\/"}]}},"_links":{"self":[{"href":"https:\/\/beckerpumps.com\/latam\/wp-json\/wp\/v2\/posts\/6497","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/beckerpumps.com\/latam\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/beckerpumps.com\/latam\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/beckerpumps.com\/latam\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/beckerpumps.com\/latam\/wp-json\/wp\/v2\/comments?post=6497"}],"version-history":[{"count":0,"href":"https:\/\/beckerpumps.com\/latam\/wp-json\/wp\/v2\/posts\/6497\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/beckerpumps.com\/latam\/wp-json\/wp\/v2\/media\/6499"}],"wp:attachment":[{"href":"https:\/\/beckerpumps.com\/latam\/wp-json\/wp\/v2\/media?parent=6497"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/beckerpumps.com\/latam\/wp-json\/wp\/v2\/categories?post=6497"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/beckerpumps.com\/latam\/wp-json\/wp\/v2\/tags?post=6497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}